text.skipToContent text.skipToNavigation

Leakage current clamp CM 9-1 measuring range 0.010 mA-60 A AC opening of pliers


Benning CM 9-1 True RMS leakage current clamp. Fault-related leakage currents are caused by insulation weaknesses or damage. With the CM 9-1, all sources of faults can be localised quickly and precisely. Preventive measurements can avoid possible damage caused by uncontrolled leakage currents in advance. Reliable and simple detection of insulation fault

Cod Articol 8A130731
Tip de curent AC
Indicație Digital
Selectarea domeniului de măsurare Automat
Domeniul de măsurare a curentului, AC (A) ['0000001', '60']
Domeniu de măsurare a curentului, DC (A) ['0', '0']
Ambalat la 1

Specificații

Tip de curent AC
Indicație Digital
Selectarea domeniului de măsurare Automat
Domeniul de măsurare a curentului, AC (A) ['0000001', '60']
Domeniu de măsurare a curentului, DC (A) ['0', '0']
Domeniu de măsurare a rezistenței Da
Deschiderea fălcii (mm) 23
Măsurare RMS adevărat Da
Test de continuitate Da
Interfață Nu
Măsurarea capacității Nu
Măsurarea frecvenței Nu
Măsurarea puterii Nu
Măsurarea curentului de scurgere Da
Măsurare în cabluri cu conductor for- și back conductor Nu
Versiune ca adaptor pentru conectarea la contorul multiplu Nu
Măsurarea arcului superior Nu
Măsurarea tensiunii, AC Da
Măsurarea tensiunii, DC Da
Afișaj analogic cu bară grafică Nu
Afișaj multiplu Nu
Categoria de circuit de măsurare CAT IV
Grad de protecție (IP) IP30
Măsurarea temperaturii Nu
Categoria de circuit de măsurare a tensiunii maxime (V) 300
Cu iluminare de fundal a afișajului Da

Descriere

Benning CM 9-1 True RMS leakage current clamp. Fault-related leakage currents are caused by insulation weaknesses or damage. With the CM 9-1, all sources of faults can be localised quickly and precisely. Preventive measurements can avoid possible damage caused by uncontrolled leakage currents in advance. Reliable and simple detection of insulation faults, e.g. defective cables, loose terminals, contamination, moisture. Measurement of leakage, residual, protective conductor and load currents in electrical systems, devices and machines. Digital display. 4-digit LCD display (6000 dots). With screen backlighting. Leakage current measurement. Current measuring range/AC 0.000001 A - 60 A. AC current type. Highest resolution of 1 µA in the 6 mA measuring range. Measurement without switch-off during normal operation of the system/device. Ideal for preventive maintenance and troubleshooting, protection against property damage and personal injury, power failures, etc.. Voltage measurement/AC 0.01 V - 600 V. Voltage measurement/DC 0.01 V - 600 V. Resistance measuring range 0.1 Ohm - 600 kOhm. Continuity test yes. True RMS value measurement (TRMS) yes Frequency characteristics in accordance with EN 61557-16 for testing electrical devices in accordance with VDE 0701-0702. LPF low-pass filter (40-70 Hz) for suppressing high-frequency interference signals. Frequency range for railway and industry 15 Hz - 1 kHz (fg). Defined protection against external magnetic fields in accordance with EN 61557-13, class 2, 30A/m. Automatic measuring range selection. Automatic switch-off. Automatic low battery indicator. Instantaneous value memory Hold. Peak value memory PEAK. Reliable shielding against external fields. Clamp opening 23 mm. Measuring circuit category Cat IV. Max. Max. voltage measuring circuit category 300 V. Measuring circuit category Cat III. Voltage measuring circuit category 600 V. Includes case, test lead set, 2 x 1.5 V Micro/ AAA/ LR03 battery.

Numerele articolelor

Cod Articol 8A130731
EAN 4014651446823
UBB 500583385546
UNSPSC 27112104
Nr. articol producător 044682
Nu închideți această pagină. Acest mesaj va dispărea când pagina este complet încărcată.