text.skipToContent text.skipToNavigation

Leakage current clamp CM 9-1 measuring range 0.010 mA-60 A AC opening of pliers


Benning CM 9-1 True RMS leakage current clamp. Fault-related leakage currents are caused by insulation weaknesses or damage. With the CM 9-1, all sources of faults can be localised quickly and precisely. Preventive measurements can avoid possible damage caused by uncontrolled leakage currents in advance. Reliable and simple detection of insulation fault

Cikkszám 8A130731
Az áram típusa AC
Jelzés Digitális
Mérési tartomány kiválasztása Automatikus
Árammérési tartomány, AC (A) ['0000001', '60']
Árammérési tartomány, DC (A) ['0', '0']
Csomagolás: 1

Műszaki adatok

Az áram típusa AC
Jelzés Digitális
Mérési tartomány kiválasztása Automatikus
Árammérési tartomány, AC (A) ['0000001', '60']
Árammérési tartomány, DC (A) ['0', '0']
Ellenállás mérési tartomány Igen
Pofa nyitása (mm) 23
True RMS mérés Igen
Folyamatossági vizsgálat Igen
Interfész Nem
Kapacitásmérés Nem
Frekvenciamérés Nem
Teljesítménymérés Nem
Szivárgási áram mérése Igen
Mérés elő- és hátvezetővel ellátott kábelekben Nem
Adapteres változat a multiméterhez való csatlakoztatáshoz Nem
Felső donga mérés Nem
Feszültségmérés, AC Igen
Feszültségmérés, egyenáram Igen
Analóg oszlopdiagram kijelző Nem
Többszörös kijelző Nem
Mérőáramkör kategória CAT IV
Védettségi fok (IP) IP30
Hőmérsékletmérés Nem
Max. feszültség mérési áramköri kategória (V) 300
Kijelző háttérvilágítással Igen

Leírás

Benning CM 9-1 True RMS leakage current clamp. Fault-related leakage currents are caused by insulation weaknesses or damage. With the CM 9-1, all sources of faults can be localised quickly and precisely. Preventive measurements can avoid possible damage caused by uncontrolled leakage currents in advance. Reliable and simple detection of insulation faults, e.g. defective cables, loose terminals, contamination, moisture. Measurement of leakage, residual, protective conductor and load currents in electrical systems, devices and machines. Digital display. 4-digit LCD display (6000 dots). With screen backlighting. Leakage current measurement. Current measuring range/AC 0.000001 A - 60 A. AC current type. Highest resolution of 1 µA in the 6 mA measuring range. Measurement without switch-off during normal operation of the system/device. Ideal for preventive maintenance and troubleshooting, protection against property damage and personal injury, power failures, etc.. Voltage measurement/AC 0.01 V - 600 V. Voltage measurement/DC 0.01 V - 600 V. Resistance measuring range 0.1 Ohm - 600 kOhm. Continuity test yes. True RMS value measurement (TRMS) yes Frequency characteristics in accordance with EN 61557-16 for testing electrical devices in accordance with VDE 0701-0702. LPF low-pass filter (40-70 Hz) for suppressing high-frequency interference signals. Frequency range for railway and industry 15 Hz - 1 kHz (fg). Defined protection against external magnetic fields in accordance with EN 61557-13, class 2, 30A/m. Automatic measuring range selection. Automatic switch-off. Automatic low battery indicator. Instantaneous value memory Hold. Peak value memory PEAK. Reliable shielding against external fields. Clamp opening 23 mm. Measuring circuit category Cat IV. Max. Max. voltage measuring circuit category 300 V. Measuring circuit category Cat III. Voltage measuring circuit category 600 V. Includes case, test lead set, 2 x 1.5 V Micro/ AAA/ LR03 battery.

Cikkszámok

Cikkszám 8A130731
EAN 4014651446823
UBB 500583385546
UNSPSC 27112104
Gyártó cikksz 044682
Ne zárja be ezt az oldalt. Ez az üzenet eltűnik, amikor az oldal teljesen betöltődik.