text.skipToContent text.skipToNavigation
Chceli by sme Vás informovať, že v termíne od 21.12.2024 do 01.01.2025 bude zákaznícky servis zatvorený . Vaše objednávky a požiadavky budú spracované od 02.01.2025. Ďakujeme za pochopenie a prajeme krásne sviatky!

Leakage current clamp CM 9-1 measuring range 0.010 mA-60 A AC opening of pliers


Benning CM 9-1 True RMS leakage current clamp. Fault-related leakage currents are caused by insulation weaknesses or damage. With the CM 9-1, all sources of faults can be localised quickly and precisely. Preventive measurements can avoid possible damage caused by uncontrolled leakage currents in advance. Reliable and simple detection of insulation fault

Položka č. 8A130731
Typ prúdu AC
Indikácia Digitálny
Výber meracieho rozsahu Automaticky
Rozsah merania prúdu, striedavý prúd (A) ['0000001', '60']
Rozsah merania prúdu, DC (A) ['0', '0']
Ambalat la 1

technické údaje

Typ prúdu AC
Indikácia Digitálny
Výber meracieho rozsahu Automaticky
Rozsah merania prúdu, striedavý prúd (A) ['0000001', '60']
Rozsah merania prúdu, DC (A) ['0', '0']
Rozsah merania odporu Áno
Otvorenie čeľuste (mm) 23
Meranie skutočnej efektívnej hodnoty Áno
Test kontinuity Áno
Rozhranie Nie
Meranie kapacity Nie
Meranie frekvencie Nie
Meranie výkonu Nie
Meranie unikajúceho prúdu Áno
Meranie v kábloch s predným a zadným vodičom Nie
Verzia ako adaptér na pripojenie k multimetru Nie
Meranie horného oblúka Nie
Meranie napätia, AC Áno
Meranie napätia, DC Áno
Analógový stĺpcový displej Nie
Viacnásobné zobrazenie Nie
Kategória meracieho obvodu CAT IV
Stupeň ochrany (IP) IP30
Meranie teploty Nie
Kategória meracieho obvodu max. napätia (V) 300
S podsvietením displeja Áno
Značka Benning

Popis

Benning CM 9-1 True RMS leakage current clamp. Fault-related leakage currents are caused by insulation weaknesses or damage. With the CM 9-1, all sources of faults can be localised quickly and precisely. Preventive measurements can avoid possible damage caused by uncontrolled leakage currents in advance. Reliable and simple detection of insulation faults, e.g. defective cables, loose terminals, contamination, moisture. Measurement of leakage, residual, protective conductor and load currents in electrical systems, devices and machines. Digital display. 4-digit LCD display (6000 dots). With screen backlighting. Leakage current measurement. Current measuring range/AC 0.000001 A - 60 A. AC current type. Highest resolution of 1 µA in the 6 mA measuring range. Measurement without switch-off during normal operation of the system/device. Ideal for preventive maintenance and troubleshooting, protection against property damage and personal injury, power failures, etc.. Voltage measurement/AC 0.01 V - 600 V. Voltage measurement/DC 0.01 V - 600 V. Resistance measuring range 0.1 Ohm - 600 kOhm. Continuity test yes. True RMS value measurement (TRMS) yes Frequency characteristics in accordance with EN 61557-16 for testing electrical devices in accordance with VDE 0701-0702. LPF low-pass filter (40-70 Hz) for suppressing high-frequency interference signals. Frequency range for railway and industry 15 Hz - 1 kHz (fg). Defined protection against external magnetic fields in accordance with EN 61557-13, class 2, 30A/m. Automatic measuring range selection. Automatic switch-off. Automatic low battery indicator. Instantaneous value memory Hold. Peak value memory PEAK. Reliable shielding against external fields. Clamp opening 23 mm. Measuring circuit category Cat IV. Max. Max. voltage measuring circuit category 300 V. Measuring circuit category Cat III. Voltage measuring circuit category 600 V. Includes case, test lead set, 2 x 1.5 V Micro/ AAA/ LR03 battery.

Čísla materiálu

Položka č. 8A130731
EAN 4014651446823
UBB 500583385546
UNSPSC 27112104
Číslo materiálu výrobcu 044682
Nezatvárajte túto stránku. Táto správa zmizne, keď sa stránka úplne načíta.