text.skipToContent text.skipToNavigation

Leakage current clamp CM 9-1 measuring range 0.010 mA-60 A AC opening of pliers


Benning CM 9-1 True RMS leakage current clamp. Fault-related leakage currents are caused by insulation weaknesses or damage. With the CM 9-1, all sources of faults can be localised quickly and precisely. Preventive measurements can avoid possible damage caused by uncontrolled leakage currents in advance. Reliable and simple detection of insulation fault

Article number 8A130731
Type of current AC
Indication Digital
Measuring range selection Automatic
Current measuring range, AC (A) ['0000001', '60']
Zakres pomiaru prądu, DC (A) ['0', '0']
Packed per 1

Specifications

Type of current AC
Indication Digital
Measuring range selection Automatic
Current measuring range, AC (A) ['0000001', '60']
Zakres pomiaru prądu, DC (A) ['0', '0']
Widerstandsmessbereich Ja
Otwieranie szczęk (mm) 23
True RMS measurement Yes
Test kontinuity Áno
Interface No
Capacitance measurement No
Frequency measurement No
Power measuring No
Leakage current measuring Yes
Measurement in cables with for- and back conductor No
Wersja jako adapter do podłączenia do miernika uniwersalnego Nie
Top arbour measurement No
Voltage measurement, AC Yes
Voltage measurement, DC Yes
Analogue bar graph display No
Wyświetlacz wielokrotny Nie
Measuring circuit category CAT IV
Stopień ochrony (IP) IP30
Messung der Temperatur Nein
Max. voltage measuring circuit category (V) 300
S podsvietením displeja Áno
Brand Benning

Description

Benning CM 9-1 True RMS leakage current clamp. Fault-related leakage currents are caused by insulation weaknesses or damage. With the CM 9-1, all sources of faults can be localised quickly and precisely. Preventive measurements can avoid possible damage caused by uncontrolled leakage currents in advance. Reliable and simple detection of insulation faults, e.g. defective cables, loose terminals, contamination, moisture. Measurement of leakage, residual, protective conductor and load currents in electrical systems, devices and machines. Digital display. 4-digit LCD display (6000 dots). With screen backlighting. Leakage current measurement. Current measuring range/AC 0.000001 A - 60 A. AC current type. Highest resolution of 1 µA in the 6 mA measuring range. Measurement without switch-off during normal operation of the system/device. Ideal for preventive maintenance and troubleshooting, protection against property damage and personal injury, power failures, etc.. Voltage measurement/AC 0.01 V - 600 V. Voltage measurement/DC 0.01 V - 600 V. Resistance measuring range 0.1 Ohm - 600 kOhm. Continuity test yes. True RMS value measurement (TRMS) yes Frequency characteristics in accordance with EN 61557-16 for testing electrical devices in accordance with VDE 0701-0702. LPF low-pass filter (40-70 Hz) for suppressing high-frequency interference signals. Frequency range for railway and industry 15 Hz - 1 kHz (fg). Defined protection against external magnetic fields in accordance with EN 61557-13, class 2, 30A/m. Automatic measuring range selection. Automatic switch-off. Automatic low battery indicator. Instantaneous value memory Hold. Peak value memory PEAK. Reliable shielding against external fields. Clamp opening 23 mm. Measuring circuit category Cat IV. Max. Max. voltage measuring circuit category 300 V. Measuring circuit category Cat III. Voltage measuring circuit category 600 V. Includes case, test lead set, 2 x 1.5 V Micro/ AAA/ LR03 battery.

Article numbers

Article number 8A130731
EAN 4014651446823
UBB 500583385546
UNSPSC 27112104
Manufacturer article nr  044682
Do not close this page. This message will disappear, when the page is fully loaded.